1,830 research outputs found

    'Designer atoms' for quantum metrology

    Get PDF
    Entanglement is recognized as a key resource for quantum computation and quantum cryptography. For quantum metrology, the use of entangled states has been discussed and demonstrated as a means of improving the signal-to-noise ratio. In addition, entangled states have been used in experiments for efficient quantum state detection and for the measurement of scattering lengths. In quantum information processing, manipulation of individual quantum bits allows for the tailored design of specific states that are insensitive to the detrimental influences of an environment. Such 'decoherence-free subspaces' protect quantum information and yield significantly enhanced coherence times. Here we use a decoherence-free subspace with specifically designed entangled states to demonstrate precision spectroscopy of a pair of trapped Ca+ ions; we obtain the electric quadrupole moment, which is of use for frequency standard applications. We find that entangled states are not only useful for enhancing the signal-to-noise ratio in frequency measurements - a suitably designed pair of atoms also allows clock measurements in the presence of strong technical noise. Our technique makes explicit use of non-locality as an entanglement property and provides an approach for 'designed' quantum metrology

    A Factorization Law for Entanglement Decay

    Full text link
    We present a simple and general factorization law for quantum systems shared by two parties, which describes the time evolution of entanglement upon passage of either component through an arbitrary noisy channel. The robustness of entanglement-based quantum information processing protocols is thus easily and fully characterized by a single quantity.Comment: 4 pages, 5 figure

    Feasibility of neuromuscular training in patients with severe hip or knee OA: The individualized goal-based NEMEX-TJR training program

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Although improvements are achieved by general exercise, training to improve sensorimotor control may be needed for people with osteoarthritis (OA). The aim was to apply the principles of neuromuscular training, which have been successfully used in younger and middle-aged patients with knee injuries, to older patients with severe hip or knee OA. We hypothesized that the training program was feasible, determined as: 1) at most acceptable self-reported pain following training; 2) decreased or unchanged pain during the training period; 3) few joint specific adverse events related to training, and 4) achieved progression of training level during the training period.</p> <p>Methods</p> <p>Seventy-six patients, between 60 and 77 years, with severe hip (n = 38, 55% women) or knee OA (n = 38, 61% women) underwent an individualized, goal-based neuromuscular training program (NEMEX-TJR) in groups for a median of 11 weeks (quartiles 7 to 15) prior to total joint replacement (TJR). Pain was self-reported immediately after each training session on a 0 to 10 cm, no pain to pain as bad as it could be, scale, where 0-2 indicates safe, > 2 to 5 acceptable and > 5 high risk pain. Joint specific adverse events were: not attending or ceasing training because of increased pain/problems in the index joint related to training, and self-reported pain > 5 after training. The level of difficulty of training was registered.</p> <p>Results</p> <p>Patients with severe OA of the hip or knee reported safe pain (median 2 cm) after training. Self-reported pain was lower at training sessions 10 and 20 (p = 0.04) and unchanged at training sessions 5 and 15 (p = 0.170, p = 0.161) compared with training session 1. There were no joint specific adverse events in terms of not attending or ceasing training. Few patients (n = 17, 22%) reported adverse events in terms of self-reported pain > 5 after one or more training sessions. Progression of training level was achieved over time (p < 0.001).</p> <p>Conclusions</p> <p>The NEMEX-TJR training program is feasible in patients with severe hip or knee OA, in terms of safe self-reported pain following training, decreased or unchanged pain during the training period, few joint specific adverse events, and achieved progression of training level during the training period.</p

    How simple can a model of an empty viral capsid be? Charge distributions in viral capsids

    Full text link
    We investigate and quantify salient features of the charge distributions on viral capsids. Our analysis combines the experimentally determined capsid geometry with simple models for ionization of amino acids, thus yielding the detailed description of spatial distribution for positive and negative charge across the capsid wall. The obtained data is processed in order to extract the mean radii of distributions, surface charge densities and dipole moment densities. The results are evaluated and examined in light of previously proposed models of capsid charge distributions, which are shown to have to some extent limited value when applied to real viruses.Comment: 10 pages, 10 figures; accepted for publication in Journal of Biological Physic

    Serum levels of Cartilage Oligomeric Matrix Protein (COMP) increase temporarily after physical exercise in patients with knee osteoarthritis

    Get PDF
    BACKGROUND: COMP (Cartilage oligomeric matrix protein) is a matrix protein, which is currently studied as a potential serum marker for cartilage processes in osteoarthritis (OA). The influence of physical exercise on serum COMP is not fully elucidated. The objective of the present study was to monitor serum levels of COMP during a randomised controlled trial of physical exercise vs. standardised rest in individuals with symptomatic and radiographic knee OA. METHODS: Blood samples were collected from 58 individuals at predefined time points before and after exercise or rest, one training group and one control group. The physical exercise consisted of a one-hour supervised session twice a week and daily home exercises. In a second supplementary study 7 individuals were subjected to the same exercise program and sampling of blood was performed at fixed intervals before, immediately after, 30 and 60 minutes after the exercise session and then with 60 minutes interval for another five hours after exercise to monitor the short-term changes of serum COMP. COMP was quantified with a sandwich-ELISA (AnaMar Medical, Lund, Sweden). RESULTS: Before exercise or rest no significant differences in COMP levels were seen between the groups. After 60 minutes exercise serum COMP levels increased (p < 0.001). After 60 minutes of rest the serum levels decreased (p = 0.003). Median serum COMP values in samples obtained prior to exercise or rest at baseline and after 24 weeks did not change between start and end of the study. In the second study serum COMP was increased immediately after exercise (p = 0.018) and had decreased to baseline levels after 30 minutes. CONCLUSION: Serum COMP levels increased during exercise in individuals with knee OA, whereas levels decreased during rest. The increased serum COMP levels were normalized 30 minutes after exercise session, therefore we suggest that samples of blood for analysis of serum COMP should be drawn after at least 30 minutes rest in a seated position. No increase was seen after a six-week exercise program indicating that any effect of individualized supervised exercise on cartilage turnover is transient

    Ultrasound-guided breast-sparing surgery to improve cosmetic outcomes and quality of life. A prospective multicentre randomised controlled clinical trial comparing ultrasound-guided surgery to traditional palpation-guided surgery (COBALT trial)

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Breast-conserving surgery for breast cancer was developed as a method to preserve healthy breast tissue, thereby improving cosmetic outcomes. Thus far, the primary aim of breast-conserving surgery has been the achievement of tumour-free resection margins and prevention of local recurrence, whereas the cosmetic outcome has been considered less important. Large studies have reported poor cosmetic outcomes in 20-40% of patients after breast-conserving surgery, with the volume of the resected breast tissue being the major determinant. There is clear evidence for the efficacy of ultrasonography in the resection of nonpalpable tumours. Surgical resection of palpable breast cancer is performed with guidance by intra-operative palpation. These palpation-guided excisions often result in an unnecessarily wide resection of adjacent healthy breast tissue, while the rate of tumour-involved resection margins is still high. It is hypothesised that the use of intra-operative ultrasonography in the excision of palpable breast cancer will improve the ability to spare healthy breast tissue while maintaining or even improving the oncological margin status. The aim of this study is to compare ultrasound-guided surgery for palpable tumours with the standard palpation-guided surgery in terms of the extent of healthy breast tissue resection, the percentage of tumour-free margins, cosmetic outcomes and quality of life.</p> <p>Methods/design</p> <p>In this prospective multicentre randomised controlled clinical trial, 120 women who have been diagnosed with palpable early-stage (T1-2N0-1) primary invasive breast cancer and deemed suitable for breast-conserving surgery will be randomised between ultrasound-guided surgery and palpation-guided surgery. With this sample size, an expected 20% reduction of resected breast tissue and an 18% difference in tumour-free margins can be detected with a power of 80%. Secondary endpoints include cosmetic outcomes and quality of life. The rationale, study design and planned analyses are described.</p> <p>Conclusion</p> <p>The COBALT trial is a prospective, multicentre, randomised controlled study to assess the efficacy of ultrasound-guided breast-conserving surgery in patients with palpable early-stage primary invasive breast cancer in terms of the sparing of breast tissue, oncological margin status, cosmetic outcomes and quality of life.</p> <p>Trial Registration Number</p> <p>Netherlands Trial Register (NTR): <a href="http://www.trialregister.nl/trialreg/admin/rctview.asp?TC=2579">NTR2579</a></p

    Measurement of the branching fraction and CP content for the decay B(0) -> D(*+)D(*-)

    Get PDF
    This is the pre-print version of the Article. The official published version can be accessed from the links below. Copyright @ 2002 APS.We report a measurement of the branching fraction of the decay B0→D*+D*- and of the CP-odd component of its final state using the BABAR detector. With data corresponding to an integrated luminosity of 20.4  fb-1 collected at the Υ(4S) resonance during 1999–2000, we have reconstructed 38 candidate signal events in the mode B0→D*+D*- with an estimated background of 6.2±0.5 events. From these events, we determine the branching fraction to be B(B0→D*+D*-)=[8.3±1.6(stat)±1.2(syst)]×10-4. The measured CP-odd fraction of the final state is 0.22±0.18(stat)±0.03(syst).This work is supported by DOE and NSF (USA), NSERC (Canada), IHEP (China), CEA and CNRS-IN2P3 (France), BMBF (Germany), INFN (Italy), NFR (Norway), MIST (Russia), and PPARC (United Kingdom). Individuals have received support from the A.P. Sloan Foundation, Research Corporation, and Alexander von Humboldt Foundation

    Measurement of D-s(+) and D-s(*+) production in B meson decays and from continuum e(+)e(-) annihilation at √s=10.6 GeV

    Get PDF
    This is the pre-print version of the Article. The official published version can be accessed from the links below. Copyright @ 2002 APSNew measurements of Ds+ and Ds*+ meson production rates from B decays and from qq̅ continuum events near the Υ(4S) resonance are presented. Using 20.8 fb-1 of data on the Υ(4S) resonance and 2.6 fb-1 off-resonance, we find the inclusive branching fractions B(B⃗Ds+X)=(10.93±0.19±0.58±2.73)% and B(B⃗Ds*+X)=(7.9±0.8±0.7±2.0)%, where the first error is statistical, the second is systematic, and the third is due to the Ds+→φπ+ branching fraction uncertainty. The production cross sections σ(e+e-→Ds+X)×B(Ds+→φπ+)=7.55±0.20±0.34pb and σ(e+e-→Ds*±X)×B(Ds+→φπ+)=5.8±0.7±0.5pb are measured at center-of-mass energies about 40 MeV below the Υ(4S) mass. The branching fractions ΣB(B⃗Ds(*)+D(*))=(5.07±0.14±0.30±1.27)% and ΣB(B⃗Ds*+D(*))=(4.1±0.2±0.4±1.0)% are determined from the Ds(*)+ momentum spectra. The mass difference m(Ds+)-m(D+)=98.4±0.1±0.3MeV/c2 is also measured.This work was supported by DOE and NSF (USA), NSERC (Canada), IHEP (China), CEA and CNRS-IN2P3 (France), BMBF (Germany), INFN (Italy), NFR (Norway), MIST (Russia), and PPARC (United Kingdom). Individuals have received support from the Swiss NSF, A. P. Sloan Foundation, Research Corporation, and Alexander von Humboldt Foundation

    Search for rare quark-annihilation decays, B --> Ds(*) Phi

    Full text link
    We report on searches for B- --> Ds- Phi and B- --> Ds*- Phi. In the context of the Standard Model, these decays are expected to be highly suppressed since they proceed through annihilation of the b and u-bar quarks in the B- meson. Our results are based on 234 million Upsilon(4S) --> B Bbar decays collected with the BABAR detector at SLAC. We find no evidence for these decays, and we set Bayesian 90% confidence level upper limits on the branching fractions BF(B- --> Ds- Phi) Ds*- Phi)<1.2x10^(-5). These results are consistent with Standard Model expectations.Comment: 8 pages, 3 postscript figues, submitted to Phys. Rev. D (Rapid Communications

    Jet energy measurement with the ATLAS detector in proton-proton collisions at root s=7 TeV

    Get PDF
    The jet energy scale and its systematic uncertainty are determined for jets measured with the ATLAS detector at the LHC in proton-proton collision data at a centre-of-mass energy of √s = 7TeV corresponding to an integrated luminosity of 38 pb-1. Jets are reconstructed with the anti-kt algorithm with distance parameters R=0. 4 or R=0. 6. Jet energy and angle corrections are determined from Monte Carlo simulations to calibrate jets with transverse momenta pT≥20 GeV and pseudorapidities {pipe}η{pipe}<4. 5. The jet energy systematic uncertainty is estimated using the single isolated hadron response measured in situ and in test-beams, exploiting the transverse momentum balance between central and forward jets in events with dijet topologies and studying systematic variations in Monte Carlo simulations. The jet energy uncertainty is less than 2. 5 % in the central calorimeter region ({pipe}η{pipe}<0. 8) for jets with 60≤pT<800 GeV, and is maximally 14 % for pT<30 GeV in the most forward region 3. 2≤{pipe}η{pipe}<4. 5. The jet energy is validated for jet transverse momenta up to 1 TeV to the level of a few percent using several in situ techniques by comparing a well-known reference such as the recoiling photon pT, the sum of the transverse momenta of tracks associated to the jet, or a system of low-pT jets recoiling against a high-pT jet. More sophisticated jet calibration schemes are presented based on calorimeter cell energy density weighting or hadronic properties of jets, aiming for an improved jet energy resolution and a reduced flavour dependence of the jet response. The systematic uncertainty of the jet energy determined from a combination of in situ techniques is consistent with the one derived from single hadron response measurements over a wide kinematic range. The nominal corrections and uncertainties are derived for isolated jets in an inclusive sample of high-pT jets. Special cases such as event topologies with close-by jets, or selections of samples with an enhanced content of jets originating from light quarks, heavy quarks or gluons are also discussed and the corresponding uncertainties are determined. © 2013 CERN for the benefit of the ATLAS collaboration
    corecore